ELECTRON
MICROSCOPY
SEM/TEM/FIBER PUSH-OUT SEM
For almost 20 years, Touchstone has been using electron microscopes
for failure analysis, corrosion investigations, coatings development,
quality control, and the development of new alloys and new composite
materials.
Touchstone takes a unique approach to electron microscopy. Most
laboratories only use electron microscopes to image samples, perform
X-ray microanalysis, and in the case of TEM's, perform microdiffraction.
Touchstone, however, regularly builds unique test fixtures which
can operate inside the electron microscope stage which provide direct
solutions to a wide variety of industrial and R&D problems.
Among these has been; the development of a device which will measure
the bond strength between the fiber and the matrix in composite
materials; observing the micromechanics of small fasteners such
as Velcro as they are engaged and disengaged; observing braze flow
characteristics of new, vacuum-brazing alloys for the aluminum industry;
and, tensile testing of small chopped fibers. Numerous other tests
are possible such as micro-scale impact tests, and scratch tests
on coatings.
Whatever your electron microscopy needs whether standard
or unique Touchstone is here to help and at a cost below most
laboratories.
Fiber PushOut SEM
To aid in the development of advanced composite materials, Touchstone
has developed a unique apparatus for characterizing the fiber-matrix
interface in composites. The interface bond and sliding characteristics
are a critical parameter controlling composite behavior. The apparatus
combines the high magnification and materials analysis capabilities
of a scanning electron microscope (SEM) with a mechanical device
for performing fiber push-out tests inside the SEM. Fibers in a
thin section of a composite are loaded using an instrumented indenter
which de-bonds and slides fibers out of the matrix material. The
resolution and depth of field of the SEM makes alignment of the
indenter possible even for the very small diameter fibers found
in many of today's composite materials. Elevated temperature push-out
tests are also possible using a modified SEM hot stage. In addition,
the instrument is capable of performing a myriad of other micro-mechanical
tests.
Measurement Features include:
- Measures De-Bond Strength and Sliding Friction
- Tests Very Small Diameter Fibers (3microns + up)
- Load vs. Displacement
- Load vs. Time
- Digital Load and Acoustic Emissions Recording
- Videotape and Digital Image Capture
- Energy Dispersive X-ray Analysis of Interface
- Displacement Rates below 7.6 Micron/Minute
- Displacements Measured to Nanometers
- Elevated Temperature Tests to 1000° C
Touchstone developed and patented this device and has installed
instruments of this design at EMPA, Thun - the Swiss Federal Laboratory;
the Army Research Laboratory in Abberdeen, MD and the University
of Southern California (USC).
Scanning Electron Microscopy (SEM)
The scanning electron microscopes at Touchstone are all equipped
with energy dispersive spectrometer (EDS) systems. These provide
a chemical analysis for any object such as inclusions that are seen
on or in a sample being viewed inside the SEM. One SEM is capable
of detecting all elements in the periodic table from the atomic
number of sodium (11 AMU) and higher. Another SEM is equipped to
also measure all elements from the atomic number of carbon (6 AMU)
and above. Both qualitative and quantitative analyses are possible.
In fact, there are numerous methods to provide quantitative analysis
on our SEM's including: ZAF, a standardless method; Matching, which
involves using stored standard spectra for comparison, and standard
based analysis. Touchstone has collected a wide range of standards
for use in X-ray microanalysis, most of which were produced by NIST.
Computer software for the image analysis of particle size and number,
grain size, and numerous other measurement.
SEM's are, with certain materials and preparation, capable of resolving
images of approximately 40 angstroms. This is usually what is quoted
by manufacturers. In normal use conditions, SEM's are limited in
resolution by the samples being examined. The typical resolution
found with steel or aluminum samples is in the range of 100 angstroms
with useful magnifications of 20 to 30,000X.
Transmission Electron Microscope
Touchstone is equipped with a TEM capable of magnification to 300,000X
and a resolution of approximately 10 angstroms. Applications include,
viewing small precipitates in agehardenable alloys, grain boundaries,
and dislocation networks. This equipment is also capable of selected
area diffraction (SAD).
Sample preparation equipment include an ultramicrotome, jet polisher
and a complete metallographic laboratory.
|